The Aviva Blood Glucose Meter is a reliable tool for monitoring blood sugar levels, designed for both home and professional use. It provides accurate results and is user-friendly, making it an essential device for effective diabetes management. The meter comes with a comprehensive guide to ensure proper setup and usage.
1.1 Overview of the Aviva Blood Glucose Meter
The Aviva Blood Glucose Meter is a portable, user-friendly device designed to measure blood sugar levels accurately. It works exclusively with Aviva test strips, offering quick results for effective diabetes monitoring. The meter is suitable for both personal and professional use, ensuring reliable performance and ease of operation for all users.
1.2 Importance of Blood Glucose Monitoring in Diabetes Management
Blood glucose monitoring is crucial for managing diabetes effectively. It helps individuals track their sugar levels, enabling timely adjustments to diet, exercise, and medication. Regular monitoring with the Aviva Blood Glucose Meter ensures better control of blood sugar levels, preventing complications and promoting overall health and well-being for those with diabetes.
Key Features and Technical Specifications
The Aviva Blood Glucose Meter features a compact, portable design, ensuring easy use anywhere. It delivers accurate results quickly and has memory capacity for tracking blood glucose levels.
2.1 Design and Portability
The Aviva Blood Glucose Meter is designed to be compact and lightweight, making it easy to carry. Its intuitive LCD interface and ergonomic design ensure ease of use. The meter is portable, allowing users to test their blood glucose levels on the go. Its sleek design and small size make it discreet for personal use anywhere.
2.2 Accuracy and Speed of Results
The Aviva Blood Glucose Meter delivers accurate blood glucose readings with rapid results, typically in just a few seconds. It employs advanced technology to ensure precise measurements, which are essential for effective diabetes management. The meter’s fast and reliable performance makes it a trusted choice for both patients and healthcare professionals.
2.3 Memory Capacity and Data Tracking
The Aviva Blood Glucose Meter features a robust memory capacity, storing up to 500 test results with dates and times. It provides averaging functionality for better tracking and offers downloadable data options for detailed analysis. This feature-rich system supports effective monitoring and diabetes management, ensuring comprehensive health insights for users.
Setting Up the Aviva Blood Glucose Meter
Setting up the Aviva Blood Glucose Meter involves unboxing, reading the manual, and installing batteries. It ensures the device is ready for accurate and reliable blood glucose monitoring.
3.1 Initial Setup and First-Time Use
Begin by carefully unpacking the Aviva Blood Glucose Meter and accessories. Read the user manual thoroughly to understand the device’s features and operation. Insert the provided batteries, ensuring correct polarity. Perform a test strip check to verify meter functionality. Set the time and date accurately for data tracking. Your meter is now ready for its first use.
3.2 Inserting Batteries and Test Strips
Insert the provided lithium battery (CR2032) into the meter, ensuring correct polarity. The meter will turn on automatically. Next, take a test strip and align it with the strip port. Gently insert the strip until it clicks. The meter will prepare for testing. Always use compatible Aviva test strips for accurate results and proper function.
3.3 Setting the Time and Date
Turn on the meter and navigate to the settings menu. Select the “Time and Date” option. Use the navigation buttons to set the current date in MM/DD/YYYY format and time in HH:MM (12-hour format with AM/PM). Press OK to save. Ensure accuracy for proper test result timestamps. Refer to the manual for detailed button sequences and confirmation steps.
Conducting a Blood Glucose Test
Prepare by washing hands and selecting a testing site. Insert a test strip into the meter, prick your finger with a lancet, and apply a blood sample. The meter will display your glucose level within seconds. Ensure proper technique for accurate results.
4.1 Preparing for the Test
Wash your hands thoroughly with soap and warm water. Choose a suitable testing site, such as a fingertip or alternative site. Gather your meter, test strips, and lancing device. Ensure the meter is turned on and ready for use. Insert a test strip into the meter, following the guide. Set the lancet depth for comfort. Have a logbook ready to record results.
4.2 Performing the Test Step-by-Step
Insert a test strip into the meter until it clicks. Use the lancing device to prick the side of your fingertip; Gently apply a blood sample to the test strip. The meter will analyze and display your blood glucose level. Store the result and dispose of the used strip properly. Keep the meter clean for accurate future tests.
4.3 Understanding Test Results
The Aviva Blood Glucose Meter displays results in mg/dL. Normal blood glucose levels typically range from 70-140 mg/dL. Elevated levels (above 140 mg/dL) may indicate hyperglycemia, while levels below 70 mg/dL suggest hypoglycemia. Use the results to adjust diet, exercise, or medication. Consult your healthcare provider for personalized interpretations and management strategies to maintain optimal blood sugar control.
Managing and Interpreting Results
Managing blood glucose results is crucial for diabetes control. Track trends, set reminders, and use data to adjust treatment plans with your healthcare provider.
5.1 Storing and Reviewing Test Data
The Aviva Blood Glucose Meter stores up to 1000 test results with dates and times. Data can be reviewed on the device or exported to a computer for tracking trends and sharing with healthcare providers. This feature helps in monitoring progress and adjusting treatment plans effectively.
5.2 Setting Reminders and Alerts
The Aviva Blood Glucose Meter allows users to set reminders for retesting after high or low readings or following meals. Alerts can be enabled for specific glucose level thresholds, ensuring timely actions. This feature helps maintain consistent monitoring and supports better diabetes management by keeping users informed and proactive about their health.
5.3 Using Results for Diabetes Management
The Aviva Blood Glucose Meter’s results help guide dietary, exercise, and medication adjustments. Regular tracking identifies trends, enabling personalized care. By analyzing patterns, users can make informed decisions to maintain target glucose levels, promoting better glycemic control and overall health outcomes for effective diabetes management.
Troubleshooting Common Issues
Common issues with the Aviva Blood Glucose Meter include error codes, test strip errors, or meter malfunctions. Refer to the user manual for specific solutions, ensuring accurate results and proper device function. Regular maintenance and correct test strip usage help minimize operational problems.
6.1 Error Messages and Solutions
Common error messages on the Aviva Blood Glucose Meter include “E-1” or “E-2,” indicating issues like invalid test strips or meter malfunctions. To resolve these, ensure strips are correctly inserted, clean the meter, and restart it. Refer to the user manual for specific error code definitions and step-by-step solutions. If issues persist, contact customer support for assistance.
6.2 Resolving Meter Malfunctions
If the Aviva Blood Glucose Meter malfunctions, check for issues like faulty test strips or low battery. Replace batteries, clean the meter, or reset it by removing and reinserting the battery. For persistent issues, refer to the user manual or contact Roche Diabetes Care support for assistance or potential replacement.
Maintenance and Care of the Meter
Regularly clean the Aviva meter with a soft cloth and mild detergent. Store it in a protective case, away from extreme temperatures and moisture to prevent damage.
7.1 Cleaning and Disinfecting the Meter
Gently clean the Aviva meter with a soft, dry cloth. For disinfecting, use a mild detergent or alcohol-based wipe, avoiding harsh chemicals. Ensure no liquids enter the meter. Regular cleaning prevents contamination and ensures accurate readings. Always follow the manual’s guidelines for proper maintenance and care to extend the meter’s lifespan and reliability.
7.2 Storing the Meter and Accessories
Store the Aviva meter in its original packaging or a protective case to prevent damage. Keep it in a cool, dry place, away from direct sunlight and extreme temperatures. Store test strips in their original container to maintain accuracy. Lancets and other accessories should be organized and kept in a safe, accessible location to ensure they remain sterile and functional.
7.3 When to Replace the Meter
Replace the Aviva Blood Glucose Meter if it exceeds its shelf life (typically 5 years from manufacture or 2 years after opening). Replace it immediately if damaged, malfunctioning, or providing inconsistent readings. Always check the expiration date on the meter or packaging to ensure accuracy and reliability in blood glucose monitoring.
Accessories and Additional Resources
The Aviva Blood Glucose Meter comes with compatible test strips, lancets, and control solutions. Additional resources include user manuals, quick-start guides, and online support for troubleshooting and maintenance;
8.1 Compatible Test Strips and Lancets
The Aviva Blood Glucose Meter requires specific Accu-Chek Aviva test strips for accurate results. Compatible lancets, such as the Accu-Chek FastClix, ensure safe and efficient blood sampling. Both items are designed to work seamlessly with the meter, providing reliable performance. These accessories are widely available for purchase separately or in starter kits.
8.2 User Manuals and Online Support
The Aviva Blood Glucose Meter comes with a detailed user manual, available online in PDF format, covering features, testing procedures, and troubleshooting. Additional support is provided through Roche Diabetes Care’s official website, including FAQs, video tutorials, and customer support contact options for assistance with device usage and maintenance.
The Aviva Blood Glucose Meter is a reliable tool for effective blood sugar monitoring, offering user-friendly design, accurate results, and comprehensive support for optimal diabetes management.
9.1 Summary of Key Points
The Aviva Blood Glucose Meter is a user-friendly device designed for accurate blood sugar monitoring. It offers reliable results, easy setup, and comprehensive support through its manual, making it an essential tool for effective diabetes management and tracking. The meter is suitable for both patients and healthcare professionals, ensuring precise and dependable glucose measurement.
9;2 Final Tips for Effective Use
Regularly clean and maintain the meter for accurate results. Use only compatible test strips and follow the manual instructions. Set reminders for testing and track your results to monitor trends. Keep the meter and accessories in a safe, dry place. Consult the user manual for troubleshooting and optimize your diabetes management with consistent use.